Maxtor LXT-200S
Stanley Gibson
b11!gibson at uunet.uu.net
Thu Aug 9 06:50:44 AEST 1990
In article <1990Aug7.003304.1753 at rice.edu> hargen at pdn.paradyne.com (Bill Hargen) writes:
>X-Sun-Spots-Digest: Volume 9, Issue 295, message 2
Maxtor LXT200 jumper information
>
>9-10: The parity disable jumper is not currently supported. When it is
>7-8: With no jumper, the disk drive does not spin up until the initiator
> issues a START/STOP UNIT command with the start bit equal to one.
> (This option is not implemented.)
On the latest revision of the drive these features are supported AND note
that they are reversed. 9-10 are start/stop and 7-8 are parity enable. By
the way Maxtor plans to replace the 200MB product with a 213MB. The new