Need Getty to work with MICOM under ULTRIX
George Robbins
grr at cbmvax.commodore.com
Sat Oct 20 10:39:00 AEST 1990
In article <5917 at nisca.ircc.ohio-state.edu> ffiaming at magnus.ircc.ohio-state.edu (Frank G. Fiamingo) writes:
> Unfortunately, the signal to change
> to the next speed is a "break". When the ULTRIX getty program
> senses the "break" it drops DTR. The MICOM senses the drop in
> DTR and breaks the connection. So instead of autobauding
> we end up disconnecting.
This is (or should be) only the case if you've specfied some kind of
security for serial lines. This is not something you'd normally want
to do, since a modem connection or simulated connection can use DSR/CD
to detect an "interrupted connection".
I'd suggest you review what security options you've enabled...
--
George Robbins - now working for, uucp: {uunet|pyramid|rutgers}!cbmvax!grr
but no way officially representing: domain: grr at cbmvax.commodore.com
Commodore, Engineering Department phone: 215-431-9349 (only by moonlite)