4.3BSD/usr/man/man4/mt.4

Compare this file to the similar file:
Show the results in this format:

.\" Copyright (c) 1980 Regents of the University of California.
.\" All rights reserved.  The Berkeley software License Agreement
.\" specifies the terms and conditions for redistribution.
.\"
.\"	@(#)mt.4	6.3 (Berkeley) 6/1/86
.\"
.TH MT 4 "June 1, 1986"
.UC 4
.SH NAME
mt \- TM78/TU-78 MASSBUS magtape interface
.SH SYNOPSIS
.B master mt0 at mba? drive ?
.br
.B tape mu0 at mt0 slave 0
.SH DESCRIPTION
The tm78/tu-78 combination provides a standard tape drive
interface as described in
.IR mtio (4).
Only 1600 and 6250 bpi are supported; the
TU-78 runs at 125 ips and autoloads tapes.
.SH "SEE ALSO"
mt(1),
tar(1),
tp(1),
mtio(4),
tm(4),
ts(4),
ut(4)
.SH DIAGNOSTICS
\fBmu%d: no write ring\fR.  An attempt was made to write on the tape drive
when no write ring was present; this message is written on the terminal of
the user who tried to access the tape.
.PP
\fBmu%d: not online\fR.  An attempt was made to access the tape while it
was offline; this message is written on the terminal of the user
who tried to access the tape.
.PP
\fBmu%d: can't change density in mid-tape\fR.  An attempt was made to write
on a tape at a different density than is already recorded on the tape.
This message is written on the terminal of the user who tried to switch
the density.
.PP
\fBmu%d: hard error bn%d mbsr=%b er=%x ds=%b\fR.   A tape error occurred
at block \fIbn\fR; the mt error register and drive status register are
printed in octal with the bits symbolically decoded.  Any error is
fatal on non-raw tape; when possible the driver will have retried
the operation which failed several times before reporting the error.
.PP
\fBmu%d: blank tape\fP.
An attempt was made to read a blank tape (a tape without even
end-of-file marks).
.PP
\fBmu%d: offline\fP.
During an i/o operation the device was set offline.  If a
non-raw tape was used in the access it is closed.
.SH BUGS
If any non-data error is encountered on non-raw tape,
it refuses to do anything more until closed.
.PP
Because 800 bpi tapes are not supported, the numbering of minor devices
is inconsistent with triple-density tape units.
Unit 0 is drive 0, 1600 bpi.