OpenSolaris_b135/cmd/fm/dicts/DISK.po

#
# Copyright 2008 Sun Microsystems, Inc.  All rights reserved.
# Use is subject to license terms.
#
# CDDL HEADER START
#
# The contents of this file are subject to the terms of the
# Common Development and Distribution License (the "License").
# You may not use this file except in compliance with the License.
#
# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
# or http://www.opensolaris.org/os/licensing.
# See the License for the specific language governing permissions
# and limitations under the License.
#
# When distributing Covered Code, include this CDDL HEADER in each
# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
# If applicable, add the following below this CDDL HEADER, with the
# fields enclosed by brackets "[]" replaced with your own identifying
# information: Portions Copyright [yyyy] [name of copyright owner]
#
# CDDL HEADER END
#
#
# DO NOT EDIT -- this file is generated by the Event Registry.
#
#
# code: DISK-8000-0X
# keys: fault.io.disk.predictive-failure
#
msgid "DISK-8000-0X.type"
msgstr "Fault"
msgid "DISK-8000-0X.severity"
msgstr "Major"
msgid "DISK-8000-0X.description"
msgstr "SMART health-monitoring firmware reported that a disk\nfailure is imminent.\n  Refer to %s for more information."
msgid "DISK-8000-0X.response"
msgstr "None.\n"
msgid "DISK-8000-0X.impact"
msgstr "It is likely that the continued operation of\nthis disk will result in data loss.\n"
msgid "DISK-8000-0X.action"
msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n"
#
# code: DISK-8000-12
# keys: fault.io.disk.over-temperature
#
msgid "DISK-8000-12.type"
msgstr "Fault"
msgid "DISK-8000-12.severity"
msgstr "Major"
msgid "DISK-8000-12.description"
msgstr "A disk's temperature exceeded the limits established by\nits manufacturer.\n  Refer to %s for more information."
msgid "DISK-8000-12.response"
msgstr "None.\n"
msgid "DISK-8000-12.impact"
msgstr "Performance degradation is likely and continued disk operation\nbeyond the temperature threshold can result in disk\ndamage and potential data loss.\n"
msgid "DISK-8000-12.action"
msgstr "Ensure that the system is properly cooled, that all fans are\nfunctional, and that there are no obstructions of airflow to the affected\ndisk.\n"
#
# code: DISK-8000-2J
# keys: fault.io.disk.self-test-failure
#
msgid "DISK-8000-2J.type"
msgstr "Fault"
msgid "DISK-8000-2J.severity"
msgstr "Critical"
msgid "DISK-8000-2J.description"
msgstr "One or more disk self tests failed.\n  Refer to %s for more information."
msgid "DISK-8000-2J.response"
msgstr "None.\n"
msgid "DISK-8000-2J.impact"
msgstr "The disk has failed.\n"
msgid "DISK-8000-2J.action"
msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n"
#
# code: DISK-8000-3E
# keys: fault.io.scsi.cmd.disk.dev.rqs.derr
#
msgid "DISK-8000-3E.type"
msgstr "Fault"
msgid "DISK-8000-3E.severity"
msgstr "Critical"
msgid "DISK-8000-3E.description"
msgstr "A non-recoverable hardware failure was detected by the device while performing a command.\n  Refer to %s for more information."
msgid "DISK-8000-3E.response"
msgstr "The device may be offlined or degraded.\n"
msgid "DISK-8000-3E.impact"
msgstr "The device has failed. The service may have been lost or degraded.\n"
msgid "DISK-8000-3E.action"
msgstr "Ensure that the latest drivers and patches are installed. Schedule a repair procedure to replace the affected\ndevice. Use 'fmadm faulty' to find the affected disk.\n"
#
# code: DISK-8000-4Q
# keys: fault.io.scsi.cmd.disk.dev.rqs.merr
#
msgid "DISK-8000-4Q.type"
msgstr "Fault"
msgid "DISK-8000-4Q.severity"
msgstr "Critical"
msgid "DISK-8000-4Q.description"
msgstr "The command was terminated with a non-recovered error condition that may have been caused by a flaw in the media or an error in the recorded data. \n  Refer to %s for more information."
msgid "DISK-8000-4Q.response"
msgstr "The device may be offlined or degraded.\n"
msgid "DISK-8000-4Q.impact"
msgstr "It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.\n"
msgid "DISK-8000-4Q.action"
msgstr "Schedule a repair procedure to replace the affected device. Use 'fmadm faulty' to find the affected disk.\n"