OpenSolaris_b135/cmd/fm/dicts/PCI.po

#
# Copyright 2009 Sun Microsystems, Inc.  All rights reserved.
# Use is subject to license terms.
#
# CDDL HEADER START
#
# The contents of this file are subject to the terms of the
# Common Development and Distribution License (the "License").
# You may not use this file except in compliance with the License.
#
# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
# or http://www.opensolaris.org/os/licensing.
# See the License for the specific language governing permissions
# and limitations under the License.
#
# When distributing Covered Code, include this CDDL HEADER in each
# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
# If applicable, add the following below this CDDL HEADER, with the
# fields enclosed by brackets "[]" replaced with your own identifying
# information: Portions Copyright [yyyy] [name of copyright owner]
#
# CDDL HEADER END
#
# DO NOT EDIT -- this file is generated by the Event Registry.
#
#
# code: PCI-8000-0C
# keys: defect.io.pci.driver
#
msgid "PCI-8000-0C.type"
msgstr "Fault"
msgid "PCI-8000-0C.severity"
msgstr "Critical"
msgid "PCI-8000-0C.description"
msgstr "A problem was detected in the PCI controller software.  Refer to %s for more information."
msgid "PCI-8000-0C.response"
msgstr "One or more of device instances may be disabled."
msgid "PCI-8000-0C.impact"
msgstr "Loss of services provided by the device instances associated with this problem."
msgid "PCI-8000-0C.action"
msgstr "Ensure latest drivers and patches are installed.  Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support."
#
# code: PCI-8000-1Q
# keys: fault.io.pci.bus
#
msgid "PCI-8000-1Q.type"
msgstr "Fault"
msgid "PCI-8000-1Q.severity"
msgstr "Critical"
msgid "PCI-8000-1Q.description"
msgstr "A problem was detected for a PCI bus.  Refer to %s for more information."
msgid "PCI-8000-1Q.response"
msgstr "One or more device instances may be disabled."
msgid "PCI-8000-1Q.impact"
msgstr "Loss of services provided by the device instances associated with this fault."
msgid "PCI-8000-1Q.action"
msgstr "Schedule a repair procedure to replace the affected device.  Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support."
#
# code: PCI-8000-24
# keys: defect.io.pci.driver fault.io.pci.bus
#
msgid "PCI-8000-24.type"
msgstr "Fault"
msgid "PCI-8000-24.severity"
msgstr "Critical"
msgid "PCI-8000-24.description"
msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
msgid "PCI-8000-24.response"
msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
msgid "PCI-8000-24.impact"
msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
msgid "PCI-8000-24.action"
msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
#
# code: PCI-8000-3R
# keys: fault.io.pci.device
#
msgid "PCI-8000-3R.type"
msgstr "Fault"
msgid "PCI-8000-3R.severity"
msgstr "Critical"
msgid "PCI-8000-3R.description"
msgstr "The system has diagnosed a problem in one or more PCI buses or devices, \nbased on the error telemetry detected by the PCI subsystem.  Refer to %s for more information."
msgid "PCI-8000-3R.response"
msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
msgid "PCI-8000-3R.impact"
msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
msgid "PCI-8000-3R.action"
msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).\n\nSchedule a repair procedure to replace the affected device."
#
# code: PCI-8000-42
# keys: defect.io.pci.driver fault.io.pci.device
#
msgid "PCI-8000-42.type"
msgstr "Fault"
msgid "PCI-8000-42.severity"
msgstr "Critical"
msgid "PCI-8000-42.description"
msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
msgid "PCI-8000-42.response"
msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
msgid "PCI-8000-42.impact"
msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
msgid "PCI-8000-42.action"
msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
#
# code: PCI-8000-5X
# keys: fault.io.pci.bus fault.io.pci.device
#
msgid "PCI-8000-5X.type"
msgstr "Fault"
msgid "PCI-8000-5X.severity"
msgstr "Critical"
msgid "PCI-8000-5X.description"
msgstr "The system has diagnosed a problem in one or more PCI buses or devices, \nbased on the error telemetry detected by the PCI subsystem.  Refer to %s for more information."
msgid "PCI-8000-5X.response"
msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
msgid "PCI-8000-5X.impact"
msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
msgid "PCI-8000-5X.action"
msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).\n\nSchedule a repair procedure to replace the affected device."
#
# code: PCI-8000-6E
# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device
#
msgid "PCI-8000-6E.type"
msgstr "Fault"
msgid "PCI-8000-6E.severity"
msgstr "Critical"
msgid "PCI-8000-6E.description"
msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
msgid "PCI-8000-6E.response"
msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
msgid "PCI-8000-6E.impact"
msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
msgid "PCI-8000-6E.action"
msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
#
# code: PCI-8000-7J
# keys: fault.io.pci.device-interr
#
msgid "PCI-8000-7J.type"
msgstr "Fault"
msgid "PCI-8000-7J.severity"
msgstr "Critical"
msgid "PCI-8000-7J.description"
msgstr "An unrecoverable problem was detected for a PCI device.\n  Refer to %s for more information."
msgid "PCI-8000-7J.response"
msgstr "One or more device instances may be disabled\n"
msgid "PCI-8000-7J.impact"
msgstr "Possible loss of services provided by the device instances associated with this fault\n"
msgid "PCI-8000-7J.action"
msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact Sun for support.\n"
#
# code: PCI-8000-8S
# keys: fault.io.pci.bus-linkerr fault.io.pci.device-interr
#
msgid "PCI-8000-8S.type"
msgstr "Fault"
msgid "PCI-8000-8S.severity"
msgstr "Critical"
msgid "PCI-8000-8S.description"
msgstr "An unrecoverable problem has been detected on the specified bus or on the specified transmitting device.\n  Refer to %s for more information."
msgid "PCI-8000-8S.response"
msgstr "One or more device instances may be disabled\n"
msgid "PCI-8000-8S.impact"
msgstr "Possible loss of services provided by the device instances associated with this fault\n"
msgid "PCI-8000-8S.action"
msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact Sun for support.\n"
#
# code: PCI-8000-95
# keys: fault.io.pci.device-invreq fault.io.pci.device-noresp
#
msgid "PCI-8000-95.type"
msgstr "Fault"
msgid "PCI-8000-95.severity"
msgstr "Major"
msgid "PCI-8000-95.description"
msgstr "Either the transmitting device sent an invalid request or the receiving device failed to respond.\n  Refer to %s for more information."
msgid "PCI-8000-95.response"
msgstr "One or more device instances may be disabled\n"
msgid "PCI-8000-95.impact"
msgstr "Possible loss of services provided by the device instances associated with this fault\n"
msgid "PCI-8000-95.action"
msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins.  Otherwise schedule a repair procedure to replace the affected device(s).  Use fmadm faulty to identify the devices or contact Sun for support.\n"
#
# code: PCI-8000-AP
# keys: fault.io.pci.device-interr fault.io.pci.device-invreq
#
msgid "PCI-8000-AP.type"
msgstr "Fault"
msgid "PCI-8000-AP.severity"
msgstr "Major"
msgid "PCI-8000-AP.description"
msgstr "Either the transmitting device sent an invalid request or the receiving device is reporting an internal fault.\n  Refer to %s for more information."
msgid "PCI-8000-AP.response"
msgstr "One or more device instances may be disabled\n"
msgid "PCI-8000-AP.impact"
msgstr "Possible loss of services provided by the device instances associated with this fault\n"
msgid "PCI-8000-AP.action"
msgstr "Ensure that the latest drivers and patches are installed.  Otherwise schedule a repair procedure to replace the affected device(s).  Use fmadm faulty to identify the devices or contact Sun for support.\n"
#
# code: PCI-8000-CA
# keys: fault.io.pci.device-noresp
#
msgid "PCI-8000-CA.type"
msgstr "Fault"
msgid "PCI-8000-CA.severity"
msgstr "Major"
msgid "PCI-8000-CA.description"
msgstr "A device is failing to respond\n  Refer to %s for more information."
msgid "PCI-8000-CA.response"
msgstr "One or more device instances may be disabled\n"
msgid "PCI-8000-CA.impact"
msgstr "Possible loss of services provided by the device instances associated with this fault\n"
msgid "PCI-8000-CA.action"
msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact Sun for support.\n"
#
# code: PCI-8000-DH
# keys: fault.io.pci.bus-linkerr-unaf fault.io.pci.device-interr-unaf
#
msgid "PCI-8000-DH.type"
msgstr "Fault"
msgid "PCI-8000-DH.severity"
msgstr "Major"
msgid "PCI-8000-DH.description"
msgstr "Too many recovered bus faults have been detected, which indicates a problem with the specified bus or with the specified transmitting device. This may degrade into an unrecoverable fault.\n  Refer to %s for more information."
msgid "PCI-8000-DH.response"
msgstr "One or more device instances may be disabled\n"
msgid "PCI-8000-DH.impact"
msgstr "Possible loss of services provided by the device instances associated with this fault\n"
msgid "PCI-8000-DH.action"
msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact Sun for support.\n"
#
# code: PCI-8000-ED
# keys: fault.io.pci.device-interr-corr
#
msgid "PCI-8000-ED.type"
msgstr "Fault"
msgid "PCI-8000-ED.severity"
msgstr "Major"
msgid "PCI-8000-ED.description"
msgstr "Too many recovered internal faults have been detected within the specified PCI device. This may degrade into a non-recoverable fault.\n  Refer to %s for more information."
msgid "PCI-8000-ED.response"
msgstr "One or more device instances may be disabled\n"
msgid "PCI-8000-ED.impact"
msgstr "Possible loss of services provided by the device instances associated with this fault\n"
msgid "PCI-8000-ED.action"
msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact Sun for support.\n"
#
# code: PCI-8000-FY
# keys: fault.io.pci.bus-linkerr-deg fault.io.pci.device-interr-deg
#
msgid "PCI-8000-FY.type"
msgstr "Fault"
msgid "PCI-8000-FY.severity"
msgstr "Major"
msgid "PCI-8000-FY.description"
msgstr "An unrecoverable problem has been detected on the specified bus or on the specified transmitting device, which has resulted in that device running in a degraded state.\n  Refer to %s for more information."
msgid "PCI-8000-FY.response"
msgstr "None\n"
msgid "PCI-8000-FY.impact"
msgstr "Degraded services provided by the device instances associated with this fault\n"
msgid "PCI-8000-FY.action"
msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact Sun for support.\n"
#
# code: PCI-8000-G3
# keys: fault.io.pci.device-interr-deg
#
msgid "PCI-8000-G3.type"
msgstr "Fault"
msgid "PCI-8000-G3.severity"
msgstr "Major"
msgid "PCI-8000-G3.description"
msgstr "An unrecoverable problem was detected for a PCI device, which has resulted in that device running in a degraded state.\n  Refer to %s for more information."
msgid "PCI-8000-G3.response"
msgstr "None\n"
msgid "PCI-8000-G3.impact"
msgstr "Degraded services provided by the device instances associated with this fault\n"
msgid "PCI-8000-G3.action"
msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact Sun for support.\n"
#
# code: PCI-8000-HR
# keys: fault.io.pci.fw_corrupt
#
msgid "PCI-8000-HR.type"
msgstr "Fault"
msgid "PCI-8000-HR.severity"
msgstr "Major"
msgid "PCI-8000-HR.description"
msgstr "A firmware corruption was detected for a PCI device.\n  Refer to %s for more information."
msgid "PCI-8000-HR.response"
msgstr "One or more device instances may be disabled.\n"
msgid "PCI-8000-HR.impact"
msgstr "Degraded services provided by the device instances associated with this fault.\n"
msgid "PCI-8000-HR.action"
msgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version or schedule a repair procedure to replace the affected device. Contact Sun support for further information.\n"
#
# code: PCI-8000-J4
# keys: fault.io.pci.fw_mismatch
#
msgid "PCI-8000-J4.type"
msgstr "Fault"
msgid "PCI-8000-J4.severity"
msgstr "Major"
msgid "PCI-8000-J4.description"
msgstr "A firmware version mismatch was detected for a PCI device.\n  Refer to %s for more information."
msgid "PCI-8000-J4.response"
msgstr "One or more device instances may be disabled.\n"
msgid "PCI-8000-J4.impact"
msgstr "Degraded services provided by the device instances associated with this fault.\n"
msgid "PCI-8000-J4.action"
msgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version. Contact Sun support for further information.\n"