OpenSolaris_b135/cmd/fm/dicts/SUN4.po

#
# Copyright 2007 Sun Microsystems, Inc.  All rights reserved.
# Use is subject to license terms.
#
# CDDL HEADER START
#
# The contents of this file are subject to the terms of the
# Common Development and Distribution License (the "License").
# You may not use this file except in compliance with the License.
#
# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
# or http://www.opensolaris.org/os/licensing.
# See the License for the specific language governing permissions
# and limitations under the License.
#
# When distributing Covered Code, include this CDDL HEADER in each
# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
# If applicable, add the following below this CDDL HEADER, with the
# fields enclosed by brackets "[]" replaced with your own identifying
# information: Portions Copyright [yyyy] [name of copyright owner]
#
# CDDL HEADER END
#
#ident	"%Z%%M%	%I%	%E% SMI"
#
# DO NOT EDIT -- this file is generated by the Event Registry.
#
#
# code: SUN4-8000-0Y
# keys: fault.io.fire.asic
#
msgid "SUN4-8000-0Y.type"
msgstr "Fault"
msgid "SUN4-8000-0Y.severity"
msgstr "Critical"
msgid "SUN4-8000-0Y.description"
msgstr "A problem was detected in the PCI-Express subsystem.\n  Refer to %s for more information."
msgid "SUN4-8000-0Y.response"
msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
msgid "SUN4-8000-0Y.impact"
msgstr "Loss of services provided by the device instances associated with this fault"
msgid "SUN4-8000-0Y.action"
msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
#
# code: SUN4-8000-13
# keys: fault.io.ebus
#
msgid "SUN4-8000-13.type"
msgstr "Fault"
msgid "SUN4-8000-13.severity"
msgstr "Critical"
msgid "SUN4-8000-13.description"
msgstr "A problem was detected in the Ebus.  Refer to %s for more information."
msgid "SUN4-8000-13.response"
msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
msgid "SUN4-8000-13.impact"
msgstr "Loss of services provided by the device instances associated with this fault"
msgid "SUN4-8000-13.action"
msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u \nEVENT_ID to collect information to help Sun Service personnel \nidentify the device in need of repair. Schedule a repair procedure to replace \nthe affected device.\n"
#
# code: SUN4-8000-2H
# keys: fault.io.datapath
#
msgid "SUN4-8000-2H.type"
msgstr "Fault"
msgid "SUN4-8000-2H.severity"
msgstr "Critical"
msgid "SUN4-8000-2H.description"
msgstr "This is an unexpected diagnosis. Please contact Sun support for details.  Refer to %s for more information."
msgid "SUN4-8000-2H.response"
msgstr "None"
msgid "SUN4-8000-2H.impact"
msgstr "None"
msgid "SUN4-8000-2H.action"
msgstr "None"
#
# code: SUN4-8000-3D
# keys: fault.io.hbus
#
msgid "SUN4-8000-3D.type"
msgstr "Fault"
msgid "SUN4-8000-3D.severity"
msgstr "Critical"
msgid "SUN4-8000-3D.description"
msgstr "A problem was detected in a system core bus.\n  Refer to %s for more information."
msgid "SUN4-8000-3D.response"
msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
msgid "SUN4-8000-3D.impact"
msgstr "Loss of services provided by the device instances associated with this fault"
msgid "SUN4-8000-3D.action"
msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp Sun Service personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n"
#
# code: SUN4-8000-4P
# keys: fault.io.fire.pciex.device
#
msgid "SUN4-8000-4P.type"
msgstr "Fault"
msgid "SUN4-8000-4P.severity"
msgstr "Critical"
msgid "SUN4-8000-4P.description"
msgstr "A problem was detected in the PCI-Express subsystem.\n  Refer to %s for more information."
msgid "SUN4-8000-4P.response"
msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
msgid "SUN4-8000-4P.impact"
msgstr "Loss of services provided by the device instances associated with this fault"
msgid "SUN4-8000-4P.action"
msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.  \nIf this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below."
#
# code: SUN4-8000-5A
# keys: defect.io.fire.pciex.driver
#
msgid "SUN4-8000-5A.type"
msgstr "Defect"
msgid "SUN4-8000-5A.severity"
msgstr "Critical"
msgid "SUN4-8000-5A.description"
msgstr "A problem was detected in the PCI-Express subsystem software.\n  Refer to %s for more information."
msgid "SUN4-8000-5A.response"
msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
msgid "SUN4-8000-5A.impact"
msgstr "Loss of services provided by the device instances associated with\nthis problem"
msgid "SUN4-8000-5A.action"
msgstr "Ensure latest driver and patch are installed.  Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support."
#
# code: SUN4-8000-6S
# keys: fault.io.datapath fault.io.fire.asic
#
msgid "SUN4-8000-6S.type"
msgstr "Fault"
msgid "SUN4-8000-6S.severity"
msgstr "Critical"
msgid "SUN4-8000-6S.description"
msgstr "This is an unexpected diagnosis. Please contact Sun support for details.  Refer to %s for more information."
msgid "SUN4-8000-6S.response"
msgstr "None"
msgid "SUN4-8000-6S.impact"
msgstr "None"
msgid "SUN4-8000-6S.action"
msgstr "None"
#
# code: SUN4-8000-75
# keys: fault.io.fire.asic fault.io.fire.pciex.device
#
msgid "SUN4-8000-75.type"
msgstr "Fault"
msgid "SUN4-8000-75.severity"
msgstr "Critical"
msgid "SUN4-8000-75.description"
msgstr "A problem was detected in the PCI-Express subsystem.\n  Refer to %s for more information."
msgid "SUN4-8000-75.response"
msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
msgid "SUN4-8000-75.impact"
msgstr "Loss of services provided by the device instances associated with this fault"
msgid "SUN4-8000-75.action"
msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
#
# code: SUN4-8000-8E
# keys: defect.io.fire.pci.driver defect.io.fire.pciex.driver
#
msgid "SUN4-8000-8E.type"
msgstr "Defect"
msgid "SUN4-8000-8E.severity"
msgstr "Critical"
msgid "SUN4-8000-8E.description"
msgstr "A problem was detected in the PCI-Express subsystem software.  Refer to %s for more information."
msgid "SUN4-8000-8E.response"
msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
msgid "SUN4-8000-8E.impact"
msgstr "Loss of services provided by the device instances associated with this problem"
msgid "SUN4-8000-8E.action"
msgstr "Ensure latest driver and patch are installed.  Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support."
#
# code: SUN4-8000-9J
# keys: fault.io.fire.pci.device fault.io.fire.pciex.device
#
msgid "SUN4-8000-9J.type"
msgstr "Fault"
msgid "SUN4-8000-9J.severity"
msgstr "Critical"
msgid "SUN4-8000-9J.description"
msgstr "This is an unexpected diagnosis. Please contact Sun support for details.  Refer to %s for more information."
msgid "SUN4-8000-9J.response"
msgstr "None"
msgid "SUN4-8000-9J.impact"
msgstr "None"
msgid "SUN4-8000-9J.action"
msgstr "None"
#
# code: SUN4-8000-A2
# keys: fault.io.fire.pci.device
#
msgid "SUN4-8000-A2.type"
msgstr "Fault"
msgid "SUN4-8000-A2.severity"
msgstr "Critical"
msgid "SUN4-8000-A2.description"
msgstr "A problem was detected in the PCI subsystem.\n  Refer to %s for more information."
msgid "SUN4-8000-A2.response"
msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
msgid "SUN4-8000-A2.impact"
msgstr "Loss of services provided by the device instances associated with this fault"
msgid "SUN4-8000-A2.action"
msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
#
# code: SUN4-8000-CX
# keys: defect.io.fire.pciex.driver fault.io.datapath fault.io.fire.asic
#
msgid "SUN4-8000-CX.type"
msgstr "Fault"
msgid "SUN4-8000-CX.severity"
msgstr "Critical"
msgid "SUN4-8000-CX.description"
msgstr "This is an unexpected diagnosis. Please contact Sun support for details.  Refer to %s for more information."
msgid "SUN4-8000-CX.response"
msgstr "None"
msgid "SUN4-8000-CX.impact"
msgstr "None"
msgid "SUN4-8000-CX.action"
msgstr "None"
#
# code: SUN4-8000-D4
# keys: fault.io.fire.asic fault.io.fire.pci.device fault.io.fire.pciex.device
#
msgid "SUN4-8000-D4.type"
msgstr "Fault"
msgid "SUN4-8000-D4.severity"
msgstr "Critical"
msgid "SUN4-8000-D4.description"
msgstr "A problem has been detected in the PCI/PCI-Express subsystem.  Refer to %s for more information."
msgid "SUN4-8000-D4.response"
msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
msgid "SUN4-8000-D4.impact"
msgstr "Loss of services provided by the device instances associated with this fault"
msgid "SUN4-8000-D4.action"
msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
#
# code: SUN4-8000-ER
# keys: fault.io.fire.asic fault.io.fire.pci.device
#
msgid "SUN4-8000-ER.type"
msgstr "Fault"
msgid "SUN4-8000-ER.severity"
msgstr "Critical"
msgid "SUN4-8000-ER.description"
msgstr "A problem has been detected in the PCI/PCI-Express subsystem.  Refer to %s for more information."
msgid "SUN4-8000-ER.response"
msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
msgid "SUN4-8000-ER.impact"
msgstr "Loss of services provided by the device instances associated with this fault"
msgid "SUN4-8000-ER.action"
msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
#
# code: SUN4-8000-FC
# keys: fault.io.fire.hbus
#
msgid "SUN4-8000-FC.type"
msgstr "Fault"
msgid "SUN4-8000-FC.severity"
msgstr "Major"
msgid "SUN4-8000-FC.description"
msgstr "A problem was detected in a system core bus.\n  Refer to %s for more information."
msgid "SUN4-8000-FC.response"
msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
msgid "SUN4-8000-FC.impact"
msgstr "Loss of services provided by the device instances associated with this fault"
msgid "SUN4-8000-FC.action"
msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp Sun Service personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n"
#
# code: SUN4-8000-GQ
# keys: fault.io.fire.datapath fault.io.fire.hbus
#
msgid "SUN4-8000-GQ.type"
msgstr "Fault"
msgid "SUN4-8000-GQ.severity"
msgstr "Critical"
msgid "SUN4-8000-GQ.description"
msgstr "Fault in either the PCIe asic's internal hostbus or connector between IO and CPU Board\n  Refer to %s for more information."
msgid "SUN4-8000-GQ.response"
msgstr "One or more device instances may be disabled\n"
msgid "SUN4-8000-GQ.impact"
msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
msgid "SUN4-8000-GQ.action"
msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
#
# code: SUN4-8000-HD
# keys: fault.io.fire.hb.sw-config
#
msgid "SUN4-8000-HD.type"
msgstr "Fault"
msgid "SUN4-8000-HD.severity"
msgstr "Critical"
msgid "SUN4-8000-HD.description"
msgstr "The IO hostbridge's hostbus has been found to be configured improperly\nwhich is preventing the system from functioning properly.\n  Refer to %s for more information."
msgid "SUN4-8000-HD.response"
msgstr "One or more device instances may be disabled\n"
msgid "SUN4-8000-HD.impact"
msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
msgid "SUN4-8000-HD.action"
msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
#
# code: SUN4-8000-JH
# keys: fault.io.fire.dmc.sw-algorithm
#
msgid "SUN4-8000-JH.type"
msgstr "Fault"
msgid "SUN4-8000-JH.severity"
msgstr "Critical"
msgid "SUN4-8000-JH.description"
msgstr "An uncorrectable software problem was detected in the IO hostbridge's \nData Management Unit which is preventing the system from functioning properly.\n  Refer to %s for more information."
msgid "SUN4-8000-JH.response"
msgstr "One or more device instances may be disabled\n"
msgid "SUN4-8000-JH.impact"
msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
msgid "SUN4-8000-JH.action"
msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
#
# code: SUN4-8000-K3
# keys: fault.io.fire.dmc.sw-state
#
msgid "SUN4-8000-K3.type"
msgstr "Fault"
msgid "SUN4-8000-K3.severity"
msgstr "Critical"
msgid "SUN4-8000-K3.description"
msgstr "The IO hostbridge's Data Management Unit has been found to be in an illegal state\nwhich is preventing the system from functioning properly.\n  Refer to %s for more information."
msgid "SUN4-8000-K3.response"
msgstr "One or more device instances may be disabled\n"
msgid "SUN4-8000-K3.impact"
msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
msgid "SUN4-8000-K3.action"
msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
#
# code: SUN4-8000-LY
# keys: fault.io.fire.pec.sw-algorithm
#
msgid "SUN4-8000-LY.type"
msgstr "Fault"
msgid "SUN4-8000-LY.severity"
msgstr "Critical"
msgid "SUN4-8000-LY.description"
msgstr "An uncorrectable software problem was detected in the IO hostbridge's \nData Management Unit which is preventing the system from functioning properly.\n  Refer to %s for more information."
msgid "SUN4-8000-LY.response"
msgstr "One or more device instances may be disabled\n"
msgid "SUN4-8000-LY.impact"
msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
msgid "SUN4-8000-LY.action"
msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"