Ultrix-3.1/sys/mdec/hkuboot.s

Compare this file to the similar file:
Show the results in this format:

/ SCCSID: @(#)hkuboot.s	3.0	4/21/86
/
//////////////////////////////////////////////////////////////////////
/   Copyright (c) Digital Equipment Corporation 1984, 1985, 1986.    /
/   All Rights Reserved. 					     /
/   Reference "/usr/src/COPYRIGHT" for applicable restrictions.      /
//////////////////////////////////////////////////////////////////////
/
/ ULTRIX-11 Block Zero Bootstrap for RK06/7 Disks
/ Boot from any unit.
/ Assumes disk at standard address (0177440).
/
/ Fred Canter
/
/ Disk boot program to load and transfer
/ to a unix file system entry.

/ ****** CONSTANTS FOR FILE SYSTEM LOGICAL BLOCK SIZE ******
/
/ For 512  byte logical blocks:
/ CLSIZE= 1, NDIRIN= 10., INOFF= 15., IGSHFT= -3, IGMASK1= !17777, IGMASK2= !7
/ For 1024 byte logical blocks:
/ CLSIZE= 2, NDIRIN= 4., INOFF= 31., IGSHFT= -4, IGMASK1= !7777, IGMASK2= !17
/
CLSIZE	= 2.		/ Physical disk blocks per logical block (cluster)
CLSHFT	= 1.		/ Shift to multiply by CLSIZE (doubles block number)
BSIZE	= 512.*CLSIZE	/ Logical block size (512 or 1024 bytes)
INOSIZ	= 64.		/ Size of an inode in bytes
NDIRIN	= 4.		/ Number of direct inode addresses (10 or 4)
ADDROFF	= 12.		/ Offset of first address in inode
INOPB	= BSIZE\/INOSIZ	/ Number of inodes per logical block (8 or 16)
INOFF	= 31.		/ Inode offset (INOPB * (SUPERB+1)) - 1  (15 or 31)
WC	= -256.*CLSIZE	/ Word count for disk transfers
IGSHFT	= -4		/ Adjust for NDIRIN in iget (-3 or -4)
IGMASK1	= !7777		/ "	"	"	"   (!17777 or 7777)
IGMASK2	= !17		/ "	"	"	"   (!7 or !17)
/
/ **********************************************************

reset	= 5
halt	= 0
nop	= 240

core	= 28.
.. = [core*2048.]-512.

/ establish sp and check if running below
/ intended origin, if so, copy
/ program up to 'core' K words.

start:
	nop		/ DEC boot block standard
	br	1f	/ "
1:
	mov	$..,sp
	clr	r0
	mov	sp,r1
	cmp	pc,r1
	bhis	2f
1:
	mov	(r0)+,(r1)+
	cmp	r1,$end
	blo	1b
	jmp	(sp)

/ clear core to make things clean
2:
	clr	(r0)+
	cmp	r0,sp
	blo	2b

/ initialize the disk hardware
/ and select the drive.
/
/ Attempt to select rk06 first,
/ if the drive can't be selected as rk06
/ then try to select it as an rk07,
/ if that fails then halt !

	mov	*$hkcs2,r1	/save booted from unit number
	bic	$!7,r1
	mov	r1,bdunit
	reset
	mov	$21,dtcmd	/rk06 drive type + read cmd
	mov	$hkcs1,r0	/Disk CSR address
	mov	r1,10(r0)	/unit select
	mov	$3,(r0)		/pack ack for rk06
1:
	tstb	(r0)		/wait for ready
	bpl	1b
	tst	(r0)		/error ?
	bpl	4f		/no, drive is rk06 !
	bit	$40,14(r0)	/yes, drive type error ?
	beq	3f		/no, fatal error
	reset			/yes, drive is not rk06
	mov	$2021,dtcmd	/rk07 drive type + read cmd
	mov	r1,10(r0)	/try rk07 unit (bdunit)
	mov	$2003,(r0)	/pack ack rk07
2:
	tstb	(r0)		/wait for ready
	bpl	2b
	tst	(r0)		/error ?
	bpl	4f		/no, continue boot
3:
	halt			/halt if can't select drive
4:

/ now start reading the inodes
/ starting at the root and
/ going through directories
	mov	$names,r1
	mov	$2,r0
1:
	clr	bno
	jsr	pc,iget
	tstb	(r1)
	beq	1f
2:
	jsr	pc,rmblk
		br rstart
	mov	$buf,r2
3:
	mov	r1,r3
	mov	r2,r4
	add	$16.,r2
	tst	(r4)+
	beq	5f
4:
	cmpb	(r3)+,(r4)+
	bne	5f
	cmp	r4,r2
	blo	4b
	mov	-16.(r2),r0
	add	$14.,r1
	br	1b
5:
	cmp	r2,$buf+BSIZE
	blo	3b
	br	2b

/ read file into core until
/ a mapping error, (no disk address)
1:
	clr	r1
1:
	jsr	pc,rmblk
		br 1f
	mov	$buf,r2
2:
	mov	(r2)+,(r1)+
	cmp	r2,$buf+BSIZE
	blo	2b
	br	1b
/ relocate core around
/ assembler header
1:
	mov	bdunit,r0	/ boot device unit number
	mov	$4,r1		/ boot device code
	mov	$hkcs1,r4	/ boot device CSR address
	clr	r5
/	cmp	(r5),$407	/ boot will always have the a.out header
/	bne	2f		/ but, it will not always be 0407!
1:
	mov	20(r5),(r5)+
	cmp	r5,sp
	blo	1b
/ enter program
2:
	clr	pc

rstart:
	movb	$'.,names+4	/ try boot.bu if bot can't be loaded
	movb	$'b,names+5
	movb	$'u,names+6
	jmp	start

/ get the inode specified in r0
iget:
	add	$INOFF,r0
	mov	r0,r5
	ash	$IGSHFT,r0
	bic	$IGMASK1,r0
	mov	r0,dno
	clr	r0
	jsr	pc,rblk
	bic	$IGMASK2,r5
	mul	$INOSIZ,r5
	add	$buf,r5
	mov	$inod,r4
1:
	mov	(r5)+,(r4)+
	cmp	r4,$inod+INOSIZ
	blo	1b
	rts	pc

/ read a mapped block
/ offset in file is in bno.
/ skip if success, no skip if fail
/ the algorithm only handles a single
/ indirect block. that means that
/ files longer than NDIRIN+128 blocks cannot
/ be loaded.
rmblk:
	add	$2,(sp)
	mov	bno,r0
	cmp	r0,$NDIRIN
	blt	1f
	mov	$NDIRIN,r0
1:
	mov	r0,-(sp)
	asl	r0
	add	(sp)+,r0
	add	$addr+1,r0
	movb	(r0)+,dno
	movb	(r0)+,dno+1
	movb	-3(r0),r0
	bne	1f
	tst	dno
	beq	2f
1:
	jsr	pc,rblk
	mov	bno,r0
	inc	bno
	sub	$NDIRIN,r0
	blt	1f
	ash	$2,r0
	mov	buf+2(r0),dno
	mov	buf(r0),r0
	bne	rblk
	tst	dno
	bne	rblk
2:
	sub	$2,(sp)
1:
	rts	pc

/ rk06 & rk07 disk driver.
/ low order address in dno,
/ high order in r0.

hkcs1	= 177440
hkda	= hkcs1+6
hkcs2	= hkcs1+10
hkds	= hkcs1+12
hkdc	= hkcs1+20

rblk:
	mov	r1,-(sp)
	mov	dno,r1
.if	CLSIZE-1
	ashc	$CLSHFT,r0		/ double blk number if 1K filsys
.endif
	div	$22.*3.,r0
	mov	r0,*$hkdc
	clr	r0
	div	$22.,r0
	swab	r0
	bis	r1,r0
	mov	$hkda,r1
	mov	r0,(r1)
	mov	$buf,-(r1)
	mov	$WC,-(r1)
	mov	dtcmd,-(r1)
1:
	tstb	(r1)
	bge	1b
	tst	(r1)
	bpl	2f
	mov	(sp)+,r1
	jmp	start
2:
	mov	(sp)+,r1
	rts	pc

/	      . b u	(try boot.bu of boot can't be loaded)
names:	<boot\0\0\0\0\0\0\0\0\0\0\0>
end:
inod = ..-256.-BSIZE
addr = inod+ADDROFF
buf = inod+INOSIZ
bno = buf+BSIZE
dtcmd = bno+2
dno = dtcmd+2
bdunit = dno+2