V3/man/man2/stty.2

Compare this file to the similar file:
Show the results in this format:

.pa 1
.he 'STTY (II)'6/12/72'STTY (II)'
.tr |
.ti 0
NAME		stty  --  set mode of typewriter
.sp
.ti 0
SYNOPSIS	(file descriptor in r0)
.br
sys stty; arg  / stty = 31.
.br
.li
...
.ti -6
arg:  dcrsr; dctsr; mode
.sp
.ti 0
DESCRIPTION	stty____
sets mode bits for a typewriter whose file descriptor
is passed in r0.
First, the system delays until the typewriter is quiescent.
Then, the argument dcrsr_____ is placed into the typewriter's
receiver control and status register,
and dctsr_____ is placed in the transmitter control and status register.
The DC-11 manual must be consulted for the format of these
words.
For the purpose of this call, the most important ro^le of
these arguments is to adjust to the speed of the typewriter.
.sp
The mode____ argument contains several bits which determine the
system's treatment of the typewriter:
.sp
.in +3
.nf
200  even parity allowed on input (e. g. for M37s)
100  odd parity allowed on input
040  raw mode: wake up on all characters
020  map CR into LF; echo LF or CR as LF-CR
010  echo (full duplex)
004  map upper case to lower on input (e. g. M33)
002  echo and print tabs as spaces
001  inhibit all function delays (e. g. CRTs)
.fi
.in -3
.sp
.fi
Characters with the wrong parity, as determined by bits 200 and
100, are ignored.
.sp
In raw mode, every character is passed back immediately
to the program.  No erase or kill processing is done;
the end-of-file character (EOT), the interrupt character
(DELETE) and the quit character (FS) are not treated specially.
.sp
Mode 020 causes input carriage returns to be turned into
new-lines;
input of either CR or LF causes LF-CR both to
be echoed
(used for GE TermiNet 300's and other terminals without the newline function).
.sp
Additional bits in the high order byte of the mode argument
are used to indicate that the terminal is an IBM|2741
and to specify 2741 modes.
These mode bits are:
.sp
.in+8
.ll+6
.ti-6
|400  terminal is an IBM|2741
.ti-6
1000  the 2741 has the transmit interrupt feature (currently ignored)
.ti-6
2000  use correspondence code conversion on output
.ti-6
4000  use correspondence code conversion on input (currently ignored)
.sp
.in -8
.ll-6
Normal input and output code conversion
for 2741s is EBCDIC (e. g. 963 ball and corresponding keyboard).
The presence of the transmit interrupt feature permits
the system to do read-ahead while no output is in progress.
In 2741 mode, the low order bits 331 are ignored.
.ti0
.sp
SEE ALSO	stty(I), gtty(II)
.sp
.ti 0
DIAGNOSTICS	The error bit
(c-bit) is set if the file descriptor does not refer to a typewriter.
.sp
.ti 0
BUGS		This call should be used with care.
.tr ||